Full Paper View Go Back

Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode

H.H. Tesfu1 , Y.K. Li2 , T. Merid3

Section:Research Paper, Product Type: Journal-Paper
Vol.8 , Issue.2 , pp.18-25, Apr-2021


Online published on Apr 30, 2021


Copyright © H.H. Tesfu, Y.K. Li, T. Merid . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
 

View this paper at   Google Scholar | DPI Digital Library


XML View     PDF Download

How to Cite this Paper

  • IEEE Citation
  • MLA Citation
  • APA Citation
  • BibTex Citation
  • RIS Citation

IEEE Style Citation: H.H. Tesfu, Y.K. Li, T. Merid, “Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode,” International Journal of Scientific Research in Chemical Sciences, Vol.8, Issue.2, pp.18-25, 2021.

MLA Style Citation: H.H. Tesfu, Y.K. Li, T. Merid "Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode." International Journal of Scientific Research in Chemical Sciences 8.2 (2021): 18-25.

APA Style Citation: H.H. Tesfu, Y.K. Li, T. Merid, (2021). Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode. International Journal of Scientific Research in Chemical Sciences, 8(2), 18-25.

BibTex Style Citation:
@article{Tesfu_2021,
author = {H.H. Tesfu, Y.K. Li, T. Merid},
title = {Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode},
journal = {International Journal of Scientific Research in Chemical Sciences},
issue_date = {4 2021},
volume = {8},
Issue = {2},
month = {4},
year = {2021},
issn = {2347-2693},
pages = {18-25},
url = {https://www.isroset.org/journal/IJSRCS/full_paper_view.php?paper_id=2365},
publisher = {IJCSE, Indore, INDIA},
}

RIS Style Citation:
TY - JOUR
UR - https://www.isroset.org/journal/IJSRCS/full_paper_view.php?paper_id=2365
TI - Simple, Fast, and Cheap Electrochemical Detection of Niclosamide Using Activated Screen Printed Carbon Electrode
T2 - International Journal of Scientific Research in Chemical Sciences
AU - H.H. Tesfu, Y.K. Li, T. Merid
PY - 2021
DA - 2021/04/30
PB - IJCSE, Indore, INDIA
SP - 18-25
IS - 2
VL - 8
SN - 2347-2693
ER -

231 Views    218 Downloads    107 Downloads
  
  

Abstract :
A simple, scalable, and low-cost electrochemically activated SPCE was prepared by LSV using 0.5M KOH. The surface of the activated-SPCE was assessed by CV and SEM and gives higher conductivity than the bare and was used for niclosamide determination. The electrochemical determination of niclosamide was analyzed in 30% DMF BRB solution pH 7.5 by SWV. Using the optimal SWV parameter linear curve in the range of 0.06 to 50 µM with 0.0051 µM limit of detection and 0.017 µM limit of quantification was obtained. The developed sensor was implemented for niclosamide determination in vegetable and urine samples and good recovery results are obtained.

Key-Words / Index Term :
Niclosamide, KOH, simple, activated, fast

References :
[1] S.M. Vliet, S. Dasgupta, N.R. Sparks, J.S. Kirkwood, A. Vollaro, M. Hur, N.I.Z. Nieden, D.C. Volz, “Maternal-to-zygotic transition as a potential target for niclosamide during early embryogenesis,” Toxicology and Applied Pharmacology, Vol.380, No.114699, pp.1-9, 2019
[2] M. Govindhan, B.R. Adhikari, S. Chen, “Nanomaterials-based electrochemical detection of chemical contaminants,” RSC Adv, Vol.4, Issue.109, pp.63741–63760, 2014.
[3] B. Kartalovi?, M. Pucarevi?, Z. Markovi?, M. Stankovi?, N. Novakov, M. Peli?, M. ?irkovi?, “Determination of Niclosamide and its Metabolites in Liver and Muscles of Common Carp (Cyprinus carpio) Fingerlings,” Acta Scientiae Veterinariae, Vol.45, No.1490, pp.1-6, 2017.
[4] Y. Yao, L. Zhang, X. Duan, J. Xu, W. Zhou, Y. Wen, “Differential pulse striping voltammetric determination of molluscicide niclosamide using three different carbon nanomaterials modified electrodes,” Electrochimica Acta, Vol.127, pp.86–94, 2014.
[5] L. Molero, M. Faundez, M.A.D. Valle, R.D. Río, F. Armijo, “Electrochemistry of methimazole on fluorine-doped tin oxide electrodes and its square-wave voltammetric determination in pharmaceutical formulations,” Electrochimica Acta, Vol.88, pp.871–876, 2013.
[6] H.G. Daabees, “Selective Differential Spectrophotometric Methods for Determination of Niclosamide and Drotaverine Hydrochloride,” Analytical Letters, Vol.33, Issue.3, pp.639–656, 2000.
[7] F. Onur, N. Tekin, “Spectrophotometric Determination of Niclosamide and Thiabendazole in Tablets,” Analytical Letters, Vol.27, Issue.12, pp.2291–2301, 1994.
[8] M. Cirkovic, B. Kartalovic, N. Novakov, M. Pelic, V. Djordjevic, V. Radosavljevic, N. Aleksic, ” Distribution of Niclosamide Residues in Meat and Internal Organs of Common Carp,” Procedia Food Science, Vol.5, pp. 54–56, 2015.
[9] C. Paghadar, N. Vadia, “Development and validation of stability indicating RP-HPLC and HPTLC for determination of Niclosamide in bulk and in synthetic mixture,” Arabian Journal of Chemistry Vol.12, pp.1803–1814, 2015.
[10] G. Doran, M.M. Stevens, “Simultaneous determination of pentachlorophenol, niclosamide and fenpropathrin in fishpond water using an LC-MS/MS method for forensic investigation,” Anal. Methods, Vol.6, Issue.17, pp.6871–6877, 2014.
[11] H. Jiang, Y. Zhang, X. Chen, J. Lv, J. Zou, “Simultaneous determination of pentachlorophenol, niclosamide and fenpropathrin in fishpond water using an LC-MS/MS method for forensic investigation,” Anal. Methods Vol. 5, Issue 5, pp. 111–115, 2013.
[12] L. LShen, Z. Li, P. He, “Electrochemical behavior of ?2-agonists at graphite nanosheet modified electrodes,” Electrochemistry Communications, Vol.12, Issue.7, pp.876–881, 2010.
[13] J.I. Gowda, A.T. Buddanavar, S.T. Nandibewoor, “Fabrication of multiwalled carbon nanotube-surfactant modified sensor for the direct determination of toxic drug 4-aminoantipyrine,” Journal of Pharmaceutical Analysis, Vol.5, Issue.4, pp.231–238, 2015.
[14] N. Talib, F. Salam, Y. Sulaiman, “ Development of Highly Sensitive Immunosensor for Clenbuterol Detection by Using Poly(3,4-ethylenedioxythiophene)/Graphene Oxide Modified Screen-Printed Carbon Electrode,” Sensors, Vol.18, Issue.18, pp.1-13, 2018.
[15] A. Kassa, M. Amare, “Electrochemical determination of paracetamol, rutin and sulfonamide in pharmaceutical formulations by using glassy carbon electrode – A Review.” Cogent Chemistry, Vol.5, Issue.1, pp.1-13, 2019.
[16] C. Huangfu, L. Fu, Y. Li, X. Li, H. Du, J. Ye, “Sensitive Stripping Determination of Cadmium(II) and Lead(II) on Disposable Graphene Modified Screen-Printed Electrode,” Electroanalysis, Vol.25, Issue.9, pp.2238–2243, 2013.
[17] P. Alagarsamy, “A Disposable Single-Use Electrochemical Sensor for Detection of Resorcinol Based on Electrochemically Activated Screen Printed Carbon Electrode in Hair Dyes,” International Journal of Electrochemical Science, Vol.12, Issue.2017, pp.6842–6852, 2017.
[18] M. González-Sánchez, B. Gómez-Monedero, J. Agrisuelas, J. Iniesta, E. Valero, “Electrochemical performance of activated screen printed carbon electrodes for hydrogen peroxide and phenol derivatives sensing,” Journal of Electroanalytical Chemistry Vol.839, pp.75–82, 2019.
[19] D. Pan, S. Rong, G. Zhang, Y. Zhang, Q. Zhou, F. Liu, M. Li, D. Chang, H. Pan, “Amperometric Determination of Dopamine Using Activated Screen-Printed Carbon Electrodes,” Electrochemistry, Vol.83, Issue.9, pp.725–729, 2015.
[20] A. Geto, M. Amare, M. Tessema, S. Admassie, “Voltammetric Determination of Nicotine at Poly(4-Amino-3-Hydroxynaphthalene Sulfonic Acid)-Modified Glassy Carbon Electrode,” Electroanalysis, Vol.24, Issue.3, pp.659–665, 2012 .
[21] C. Chapados, J.J. Max, “Infrared Spectroscopy of Aqueous Carboxylic Acids: Comparison between Different Acidsand Their Salts,” J. Phys. Chem. A, Vol. 108, Issue.16, pp. 3324 – 3337, 2004.
[22] S. Takahama, A. Johnson, L.M. Russell, “Quantification of Carboxylic and Carbonyl Functional Groups in Organic Aerosol Infrared Absorbance Spectra,” Aerosol Science and Technology, Vol.47, Issue.3, pp.310–325, 2013.
[23] Y. Mümin, H. Filik, S. Aydar, A.A. Avan, “Electrochemical Determination of Brucine in Urine with a Poly(Alizarin Red S)-modified Glassy Carbon Electrode,” Analytical Letters, Vol.49, Issue.17, pp.2716–2727, 2016.
[24] I. Hosu, D. Constantinescu-Aruxandei, M.L. Jecu, F. Oancea, M.B. Doni,. “Peroxynitrite Sensor Based on a Screen Printed Carbon Electrode Modified with a Poly(2,6-dihydroxynaphthalene) Film,” Sensors, Vol.16, Issue.11, pp.1975, 2016.
[25] N. Raghavendra, V.H. Leena, J.G. Pooja “ Expired Ixabepilone as a Corrosion Inhibitor on Copper Metal Protection in 5 M HCl Medium,” Int. J. Sci. Res. in Chemical Sciences, Vol.6, Issue.4, pp.2455-3174, 2019.
[26] A. Gamero-Quijano, F. Huerta, D. Salinas-Torres, E. Morallón, F. Montilla, “Electrocatalytic Performance of SiO2-SWCNT Nanocomposites Prepared by Electroassisted Deposition,” Electrocatalysis, Vol.4, pp.259–266, 2013.
[27] M.M. Athar, M. Zaib, “Electrochemical Evaluation of Phanerocheaete Chrysosporium Based Carbon Paste Electrode with Potassium Ferricyanide Redox System,” Int. J. Electrochem. Sci., Vol.10, Issue.8, pp.6690 – 6702, 2015.
[28] B.V.M. Zanoni, V.L.I. Rosa, R.C. Pesquero, R.N. Stradiotto, “Electrochemical Behavior of a Nitrobenzenesulfonyl Derivative of Aniline in Aqueous Solution.” J. Braz. Chem. Soc., Vol.8, No.3, pp.223-227, 1997.
[29] H.M. Elqudaby, H.A.M. Hendawy, E.R. Souaya, G.G. Mohamed, G.M.G. Eldin, “Utility of Activated Glassy Carbon and Pencil Graphite Electrodes for Voltammetric Determination of Nalbuphine Hydrochloride in Pharmaceutical and Biological Fluids,” International Journal of Electrochemistry, Vol.2016, pp.1–9, 2016.
[30] B.Rezaei, S.Damiri, “Voltammetric behavior of multi-walled carbon nanotubes modified electrode-hexacyanoferrate(II) electrocatalyst system as a sensor for determination of captopril. Sensors and Actuators B: Chemical,” Vol.134, Issue.1, pp.324–331, 2008.
[31] G.Saglikoglu, S.Yilmaz, “Voltammetric sensitive determination of metronidazole at poly(p-aminobenzene sulfonic acid)-modified glassy carbon electrode,” Russian Journal of Electrochemistry, Vol.51, No.9, pp.862–866, 2015.
[32] S. Mehretie, S. Admassie, M. Tessema, T. Solomon, “ Electrochemical study of niclosamide at poly(3,4-ethylenedioxythiophene) modified glassy carbon electrode,” Sensors and Actuators B: Chemical, Vol.168, pp.97–102, 2012.
[33] Z. Zhang, Y. Yao, J. Xu, Y. Wen, J. Zhang, W. Ding, “Nanohybrid sensor based on carboxyl functionalized graphene dispersed palygorskite for voltammetric determination of niclosamide,” Applied Clay Science, Vol.143, pp. 57–66, 2017.
[34] W.F. Bansode, K.R. Singh, P. Shukla, “Chloramphenicol Toxicity: A Review,” Journal of Medicine and Medical Sciences, Vol.2, Issue.13, pp.1313-1316, 2011.
[35] E. Dede, Ö. Sa?lam, Y. Dilgin, “Sensitive Voltammetric Determination of Niclosamide at a disposable pencil graphite electrode, ” Electrochimica Acta, Vol.127, Issue.1, pp.20–26, 2014.

Authorization Required

 

You do not have rights to view the full text article.
Please contact administration for subscription to Journal or individual article.
Mail us at  support@isroset.org or view contact page for more details.

Go to Navigation