Full Paper View Go Back
Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging
Suresh K C1 , Sathish KN2
Section:Research Paper, Product Type: Isroset-Journal
Vol.6 ,
Issue.6 , pp.116-121, Dec-2018
CrossRef-DOI: https://doi.org/10.26438/ijsrpas/v6i6.116121
Online published on Dec 31, 2018
Copyright © Suresh K C, Sathish KN . This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
View this paper at Google Scholar | DPI Digital Library
How to Cite this Paper
- IEEE Citation
- MLA Citation
- APA Citation
- BibTex Citation
- RIS Citation
IEEE Style Citation: Suresh K C, Sathish KN, “Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging,” International Journal of Scientific Research in Physics and Applied Sciences, Vol.6, Issue.6, pp.116-121, 2018.
MLA Style Citation: Suresh K C, Sathish KN "Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging." International Journal of Scientific Research in Physics and Applied Sciences 6.6 (2018): 116-121.
APA Style Citation: Suresh K C, Sathish KN, (2018). Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging. International Journal of Scientific Research in Physics and Applied Sciences, 6(6), 116-121.
BibTex Style Citation:
@article{C_2018,
author = {Suresh K C, Sathish KN},
title = {Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging},
journal = {International Journal of Scientific Research in Physics and Applied Sciences},
issue_date = {12 2018},
volume = {6},
Issue = {6},
month = {12},
year = {2018},
issn = {2347-2693},
pages = {116-121},
url = {https://www.isroset.org/journal/IJSRPAS/full_paper_view.php?paper_id=1022},
doi = {https://doi.org/10.26438/ijcse/v6i6.116121}
publisher = {IJCSE, Indore, INDIA},
}
RIS Style Citation:
TY - JOUR
DO = {https://doi.org/10.26438/ijcse/v6i6.116121}
UR - https://www.isroset.org/journal/IJSRPAS/full_paper_view.php?paper_id=1022
TI - Effective Atomic Number, Electron Density and CT Numbers of Skeletal Muscle Relaxants for Imaging
T2 - International Journal of Scientific Research in Physics and Applied Sciences
AU - Suresh K C, Sathish KN
PY - 2018
DA - 2018/12/31
PB - IJCSE, Indore, INDIA
SP - 116-121
IS - 6
VL - 6
SN - 2347-2693
ER -
Abstract :
The Effective atomic numbers Z¬¬eff , Electron density Ne and CT numbers of skeletal muscle relaxants tubocurarine chloride, gallamine triethiodide, pancuronium bromide, suxamethonium bromide and mephenesin for total and coherent, incoherent, photoelectric absorption, pair production in atomic and nuclear field photon interaction have been calculated in the wide region 1keV to 100GeV. The molecular, atomic, electronic cross sections are calculated using mass attenuation coefficient of relaxants obtained by running WinXCOM programme and finally Z¬¬eff , Ne and CT number of the relaxants have been estimated. The Z¬¬eff , and Ne have found to vary with energy and composition of the relaxants and this variation is shown graphically for all photon interaction. Even CT numbers are also not remaining constant with energy. The significance of CT number in visualizing the image of the biological samples is discussed particularly in the low energy region as this region is extensively used in the medical radiology. This helps in cross-sectional image of internal organs in the field of medicine for diagnosing the diseases. The CT number is not only outlining the inhomogeneities of the tissues but also give the direct information of the tissue electron density from which accurate corrections can be made by suitable treatments
Key-Words / Index Term :
Effective atomic number, Electron density, CT number, relaxants
References :
[1] Berger.M.J. and Hubbell.J.H XCOM: Photon cross sections on a Personal computer NBSIR 87-3597, (1987).
[2] Bhandal G. S and Singh K Effective atomic numbers studies indifferent biological samples for partial and total photon interaction in the energy region 10-3 to 105MeV.Int. J. Appl.Radiat. Isot. 44,429. (1993)
[3] Govinda Nayak. N,Vijaya .M.G,Siddappa.K. Effective atomic numbers of some polymers and other materials for Photoelectric process at 59.54KeV.61,559,(2001).
[4] Hine,G.J The effective atomic numbers of materials for various gamma interactions.Phys.Rev.85, 725, (1952).
[5] Hubbell. J H; Seltzer, S M, Tables of mass attenuation cofficients1KeV to 20MeV for elements Z=1 to Z=92 and 48 additional selected substances of dosimetric interest NISTIR-5632, (1995).
[6] Jakson. D. F and Hawkes.D. J X-ray attenuation coefficients of elements and mixtures, Phys. Reports, 70,169-233, (1981).
[7] Kiran Kumar. T, Venkataratnam.S.and Venkatreddy.KComments on theoretical limitation for experimental values of photoelectric cross sections at low energies. Nucl.instrum. meth. B108, 267, (1996).
[8] Kiran Kumar. T, Venkataratnam.S.and Venkatreddy.K. Effective atomic number studies in clay minerals for total photon interaction in the energy region 10KeV to 10 MeV. Rad.Phys.Chem.48, 707, (1996).
[9] Orhan Icelli and Salih Erzeneoglu (2004) Effective atomic numbers of some vanadium and nickel compounds for total photon interactions using transmission experiments. 4Journal of Qualitative spectroscopy and Radiative Transfer, 85, 115
[10] Parthasaradhi.K., Guruprasd.S. and Rao.B.M. (1989) Effective atomic numbers of biological materials in the energy regions 1-50 MeV for photons,electrons and He ions. Med.Phys.16,653
[11] Shivalinge Gowda, Krishnaveni.S, Ramakrishna Gowda, Studies on effective atomic number and electron density of some amino acids in the energy region 30- 1333KeV, Nucl.Inst. Meth.Phys. Res.B,239,36, (2005).
[12] Shivaramu (2002) Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs, Medical Dosimetry, 27, 1-9.
[13] Shivaramu,Amutha.R,Ramprasath.V. Effective atomic numbers and mass attenuation coefficients of some thermo luminescent dosimetric compounds for total photon interactions.Nucl.Sci.Eng 132,148 (1999)
[14] Shivramu,Ramprasath.V. Effective atomic numbers for photon-energy absorption and energy dependence of some thermo luminescent dosimetric compounds. Nucl.Inst. Meth.B168, 294/304.2000
[15] S J Thomas. Relative electron density calibration of CT scanners for radiotherapy treatment planning. The British Journal of Radiology, 72,781-786,1999
You do not have rights to view the full text article.
Please contact administration for subscription to Journal or individual article.
Mail us at support@isroset.org or view contact page for more details.